A heat pump water heater would require either 120v or 240v power connected to a 30amp breaker directly from the breaker box to the desired water heater location. The water heater may sit flat on a concrete floor using a drip pan to secure the surrounding walls. All heat pump water heaters have a condensation line that must run to the exterior of the home. Since this is an all electric water heater, this does not require any venting.